TOP > Voltage Generator > Electron-Wave Water Treatment Unit Instruction Manual

(Electron-Wave Water Treatment Unit 1/1)

Electron-Wave Water Treatment Unit
Instruction Manual

1. Product name Electron-Wave Water Treatment Unit
2. Model ME-5050-B
3. Standard configuration (1)ME-5050-B
(2)Output cord
(3)Power cord
Main body
10m
2m
One
One
One
4. Specifications Input voltage:100 Va-c +/-10%, single phase, 50/60Hz
Input current:20mA max.
Outside dimensions:154 (W) x 174 (D) x 110 (H) mm
Weight:1.4 kg (main body only)
Working temperature:-10 to +40 degrees C
Working humidity:80% max. (non-condensing)
5. Handling instructions-1. Installation
This product is a high-precision unit. Store it in a dust- and water-proof box and install the box in a room out of direct sunlight.
-2. Connection Connect the output cord to the output connector.On the metal surface of the target object (pipe flange or equipment) to be connected with the output cord terminal, peel off the paint and reveal the base metal by grinding.Ensure that the terminal and the metal surface are securely connected using bolts and nuts. The unit does not properly function in case of improper connection. Electron waves are propagated through the output cord, connection, metal, to the water, in which they are absorbed.Connect the output cord's earth cord to an earth nearby.
-3. Operation Connect the power cord to the input connector on the unit.The three lamps should light up: (1) incoming power indicator (green), (2) activation output indicator (red), and (3) lamp in inspection port.
-4. Checkup For daily checkup, verify that (2) activation output indicator (green), and (3) lamp in inspection port are lit.
6. Output cord connection target
Feed water pipe Connect the output cord to the base-side flange of the water feed pipe, or to the earth screw on the electrode holder of an elevated tank.In the case of a booster pump or pressure tank type, branch the output cord, connecting one wire of the cord to the feed water pipe connection flange of the pump and the other wire to a stainless steel part of the water receiving tank.The connections must be such that electron waves are always propagating to the water in both the feed water pipe and the water receiving tank.
Column pipe Branching the output cord, connect one wire of the cord to the discharge pipe connection flange of the lifting pipe and the other wire to a stainless steel part of the water receiving tank.The connections must be such that electron waves are always propagating to the water in both the column pipe and the water receiving tank.
Hot water pipe Connect the output cord to the supply pipe flange of the pump.
Hot-water supply pipe Connect the output cord to the supply pipe flange of the pump.
Cooling water Connect the output cord to the cooling-water supply pipe flange of the target equipment.Where a number of equipment devices are linked in a single system, connect the output cord to the supply pipe flange between the pump and the equipment.If a header is available, make the connection to the connectable metal part of the header or to the flange.

To the top of this page